Search Exchange
Search All Sites
Nagios Live Webinars
Let our experts show you how Nagios can help your organization.Login
Directory Tree
Directory
Search Results
The search results below show both sub-categories and individual listings that match your search criteria.Meet The New Nagios Core Services Platform
Built on over 25 years of monitoring experience, the Nagios Core Services Platform provides insightful monitoring dashboards, time-saving monitoring wizards, and unmatched ease of use. Use it for free indefinitely.
Monitoring Made Magically Better
- Nagios Core on Overdrive
- Powerful Monitoring Dashboards
- Time-Saving Configuration Wizards
- Open Source Powered Monitoring On Steroids
- And So Much More!
Submit Your Nagios Project!
Help build Nagios Exchange for yourself and the entire the Nagios Community by your Nagios project to the site. It's easy - just create an account, login, and add a new listing. Read the FAQ for instructions.check_hpasm





This plugin monitors the hardware health of HP Proliant Servers, provided that the hpasm (HP Advanced Server Management) software is installed. It is also able to monitor the system health of HP Bladesystems and storage systems.
check_hparray-aw





Checks HP array health (cciss/cpqarray) using hpacucli.
check_hparray





Plugin written in Bourne Shell that checks HP Proliant hardware raid via the HPACUCLI tool.
check_hpacucli-diskfailed





Bash script to check all disks in RAID arrays managed by hpacucli, it will return critical whenever a disk is in failed or in rebuild mode. I've noticed that other scripts (check_hparray) will return OK, even though a disk has failed, preventing timely no ...
check_hpacucli





Nagios plugin that checks HP RAID controller status with hpacucli, requires CPAN module Nagios::Plugin & hpacucli to be installed. To work it will need a sudoers line see NOTES in code for details.
check_hp Popular





Check CPUs, fans, array controllers, logical / physical drives, temperature and power supplies on your Proliant servers or blade systems through SNMP. As of version 2.20 you can use this plugin to retrieve performance data for Smart Array CPUs.
check_esxi_hpSmartArrayE200i_through_ssh.php





This addons check hp Smart Array E200i status on ESXi server through ssh connection. It's written in PHP.
check_esxcli_hparray





A Nagios plugin that checks HP Proliant hardware raid via the VMWare ESXCLI tool on ESXi servers with the HP Util Blunde installed (hpacucli namespace enabled). This is based on the check_hparray plugin but with the checking order corrected in order t ...
check_dp_mediapool_size





This bash script could check hp data protector pool sizes! We use it for our archivelog pool in oracle.
check_aruba_time (check_hp_time)





The script connects via SSH to an Aruba Switch (HP Switch), executes the "show time" command and then compares the result with the current time. Depending on the chosen parameters it returns OK, WARNING or CRITICAL. In case of an error it returns UNKNOWN.
check hp_iml





Check hp_iml over SNMP - a Shell-Script to check HP Integrated Management Log (IML).
Check HP UPS system status via Nagios





This article describes how to check HP UPS system status via Nagios.
Check HP switch sensor status via Nagios





This is a perl script that allows you to check sensors of HP switches via Nagios.
Check HP officejet6700 ink state





./check_hp_printer n nParts are: black, yellow, cyan and magenta nExample: ./check_hp_printer 127.0.0.1 public black 80 95
Check HP MSM760 access point





Check AP under a MSM 760 series controller and notify if some AP is not connected/sync.
Check HP MSA P2000





This checks the HP P2000 for the status of all parts within the SAN, this includes all Enclosures, Fans, Voltages, Disks and Temperatures. SNMP is not needed for this as it uses the inbuilt API to gather the status and performance counters over HTTP or HT ...
Check HP MSA (Modular Smart Array) sensors





This plugin checks all sensors of an HP MSA array. Currently successfully tested with : HP MSA2312i HP MSA2012i HP MSA2012fc HP MSA2324i HP P2000 G3 MSA (iSCSI & FC) Usage : check_msa_hardware.pl -H [ hostname | IP address ...
check HP hpacucli Array status





This plugin checks RAID Array status on hp servers via SSH. it runs remotely the command "hpacucli" in order to check if the status of the disks changed. Using this plugin, you can have under control the status of all the Arrays on your HP servers in a ...
Check Disks on HPE MSA 2050





Based on the work of Stephen Bleazard's plugin over at https://exchange.nagios.org/directory/Plugins/Hardware/Storage-Systems/RAID-Controllers/check_hp_msa2324sa_disk/details. I made some SIMPLE modifications to make it work via SSH in place of Telne ...