Search Exchange
Search All Sites
Nagios Live Webinars
Let our experts show you how Nagios can help your organization.Login
Directory Tree
HP Procurve SNMP counters
0.2s
2015-08-04
- Nagios 3.x
GPL
16103
File | Description |
---|---|
check_snmp_hp-procurve-counters.sh | Check HP Procurve SNMP counters |
Meet The New Nagios Core Services Platform
Built on over 25 years of monitoring experience, the Nagios Core Services Platform provides insightful monitoring dashboards, time-saving monitoring wizards, and unmatched ease of use. Use it for free indefinitely.
Monitoring Made Magically Better
- Nagios Core on Overdrive
- Powerful Monitoring Dashboards
- Time-Saving Configuration Wizards
- Open Source Powered Monitoring On Steroids
- And So Much More!
When certain (adjustable) thresholds are reached critical or warning signals are raised.
For example, here a switch was checked for counter errors and two issues were found for port B19.
The plugin then gets the MAC addresses connected to that port and the vendor id.
Finally it prints a description and probable cause for the issue.
Switch 10.10.10.254 got at least one CRITICAL counter for port(s): B19 B19
CRC ALIGN ERRORS/FCS 2770 on 117891520 packets (ratio less than 1%) for port B19 (ID 45) CRITICAL
MAC(s):
00-17-95-32-54-07-CISCO SYSTEMS, INC.
DESCRIPTION:
Wrong checksum or frames received that don't end with an even number of octets.
COMMON CAUSE:
Half/full duplex mismatch or faulty driver, NIC or faulty cable.
COLLISIONS 11443 on 117891520 packets (ratio less than 1%) for port B19 (ID 45) CRITICAL
MAC(s):
00-17-95-32-54-07-CISCO SYSTEMS, INC.
DESCRIPTION:
Collisions occurred before the interface trasmitted a frame to the media successfully.
COMMON CAUSE:
Normal for half-duplex interfaces; for full-duplex too much traffic for Ethernet to handle or duplex mismatch.
Now the question is: how many errors are too many?
The parameters in the script, which can be modified, are set to give:
- a warning when 5 counter errors are found every 1000 packtes (0,5%)
- a critical when 50 counter errors are found every 1000 packtes (5%)
- a critical when an absolute value of 2000 is reached for counter errors
Btw I'm open to suggestions for which could be the optimal values to use here.
The plugin has been tested with various HP models:
Reference:
http://www.hp.com/rnd/library/troubleshoot_lan.htm
http://www.cisco.com/c/en/us/support/docs/switches/catalyst-6500-series-switches/12027-53.html
Instructions.
Save the plugin in /usr/lib/nagios/plugins/ directory (or whatever directory the other plugins reside in).
Give execution rights to all for it.
Download MAC vendors file from:
http://standards-oui.ieee.org/oui.txt
Place it in the same directory of the plugin and give execution rights to all for it.
Then add the following definitions in your config.
Command definition:
# HP Procurve switch performance counters
define command {
command_name check_snmp_hp-procurve-counters
command_line $USER1$/check_snmp_hp-procurve-counters.sh $HOSTADDRESS$ $ARG1$
}
Service definition:
# HP Procurve Switch performance counters
define service {
hostgroup_name switch
service_description HP-counters
check_command check_snmp_hp-procurve-counters!public
use generic-service
}
For example, here a switch was checked for counter errors and two issues were found for port B19.
The plugin then gets the MAC addresses connected to that port and the vendor id.
Finally it prints a description and probable cause for the issue.
Switch 10.10.10.254 got at least one CRITICAL counter for port(s): B19 B19
CRC ALIGN ERRORS/FCS 2770 on 117891520 packets (ratio less than 1%) for port B19 (ID 45) CRITICAL
MAC(s):
00-17-95-32-54-07-CISCO SYSTEMS, INC.
DESCRIPTION:
Wrong checksum or frames received that don't end with an even number of octets.
COMMON CAUSE:
Half/full duplex mismatch or faulty driver, NIC or faulty cable.
COLLISIONS 11443 on 117891520 packets (ratio less than 1%) for port B19 (ID 45) CRITICAL
MAC(s):
00-17-95-32-54-07-CISCO SYSTEMS, INC.
DESCRIPTION:
Collisions occurred before the interface trasmitted a frame to the media successfully.
COMMON CAUSE:
Normal for half-duplex interfaces; for full-duplex too much traffic for Ethernet to handle or duplex mismatch.
Now the question is: how many errors are too many?
The parameters in the script, which can be modified, are set to give:
- a warning when 5 counter errors are found every 1000 packtes (0,5%)
- a critical when 50 counter errors are found every 1000 packtes (5%)
- a critical when an absolute value of 2000 is reached for counter errors
Btw I'm open to suggestions for which could be the optimal values to use here.
The plugin has been tested with various HP models:
Reference:
http://www.hp.com/rnd/library/troubleshoot_lan.htm
http://www.cisco.com/c/en/us/support/docs/switches/catalyst-6500-series-switches/12027-53.html
Instructions.
Save the plugin in /usr/lib/nagios/plugins/ directory (or whatever directory the other plugins reside in).
Give execution rights to all for it.
Download MAC vendors file from:
http://standards-oui.ieee.org/oui.txt
Place it in the same directory of the plugin and give execution rights to all for it.
Then add the following definitions in your config.
Command definition:
# HP Procurve switch performance counters
define command {
command_name check_snmp_hp-procurve-counters
command_line $USER1$/check_snmp_hp-procurve-counters.sh $HOSTADDRESS$ $ARG1$
}
Service definition:
# HP Procurve Switch performance counters
define service {
hostgroup_name switch
service_description HP-counters
check_command check_snmp_hp-procurve-counters!public
use generic-service
}
Reviews (1)
bydamned, February 12, 2016
Very useful: Well Done!!