Search Exchange

Search All Sites

Nagios Live Webinars

Let our experts show you how Nagios can help your organization.

Contact Us

Phone: 1-888-NAGIOS-1
Email: sales@nagios.com

Login

Remember Me

Directory Tree

check_hparray

Rating
8 votes
Favoured:
0
Hits
122582
Files:
FileDescription
check_hparraycheck_hparray plugin
Nagios CSP

Meet The New Nagios Core Services Platform

Built on over 25 years of monitoring experience, the Nagios Core Services Platform provides insightful monitoring dashboards, time-saving monitoring wizards, and unmatched ease of use. Use it for free indefinitely.

Monitoring Made Magically Better

  • Nagios Core on Overdrive
  • Powerful Monitoring Dashboards
  • Time-Saving Configuration Wizards
  • Open Source Powered Monitoring On Steroids
  • And So Much More!
Plugin written in Bourne Shell that checks HP Proliant hardware raid via the HPACUCLI tool.
A Nagios plugin written in Bourne Shell (sh) that checks HP Proliant hardware raid via the HPACUCLI tool. HPACUCLI is a part of the HP Support Package and is available from the http://www.hp.com.

Tested on Red Hat Enterprise Linux 4, should work with most *nix based operative systems.

In your nrpe.cfg add for example:

commandcheck_hpraid_slot1=/opt/nrpe/libexec/check_hparray -s 1
commandcheck_hpraid_slot2=/opt/nrpe/libexec/check_hparray -s 2

Will be look something like this in Nagios Status information:
---snipp---
RAID OK - (Smart Array P400 in Slot 1 array A logicaldrive 1 (68.3 GB, RAID 1+0, OK) array B logicaldrive 2 (68.3 GB, RAID 1+0, OK))
---snipp---

NOTE!
HPACUCLI needs administrator rights.
Add this line to /etc/sudoers:

nagios ALL=NOPASSWD: /usr/sbin/hpacucli
Reviews (5)
bydbentley, October 28, 2014
False positives. I had a failed drive, this script said all was dandy. I found out I had a bad drive by seeing the yellow indicator when out in the datacenter, then double checked my script and it says it was all good while a drive was indicating it was FAILED when manually running the hpacucli command.

Use check_cciss instead, much more reliable and even detects failed batteries, no need to setup different checks for multiple slots as well.
I`ve made some changes to make this plugin work on CentOS 5 and CentOS 6. I`m checking on DL380 G4, DL360 G5, DL360 G7

What I`ve done is:
Installed ProLiant Support Pack (hpacucli)
* Disabled selinux
recovery >> recover in the script. this is to properly match on status rebuilding.
nagiosuser ALL=(ALL) NOPASSWD:/usr/sbin/hpacucli
bywwalker, February 6, 2012
1 of 1 people found this review helpful
use check_cciss.

check_hparray WILL provide false positives!!

Note to the author - thank you, the tool seems to be the basis for other tools. Someone had to make the first tool. You check for OK before you check for failed :-(

Here we have a server with a failed battery and a failed array, yet check_hparray reports to nagios that all is well.


[nagios@alpha plugins]$ ./check_hparray -s 1
RAID OK - (Smart Array P800 in Slot 1 array A logicaldrive 1 (68.3 GB, RAID 1, OK) array B (Failed) logicaldrive 2 (1.2 TB, RAID 1+0, Interim Recovery Mode))
[nagios@alpha plugins]$ echo $?
0

Here is another server with a failed array that reports all is well:


-bash-3.2$ ./check_hparray -s 1
RAID OK - (Smart Array P800 in Slot 1 array A (Failed) logicaldrive 1 (68.3 GB, RAID 1, Interim Recovery Mode) array B logicaldrive 2 (1.2 TB, RAID 1+0, OK))
byzszs, July 21, 2011
1 of 1 people found this review helpful
hpacucli shows a "Failed" disk but plugin says that "RAID: OK" and exits with 0
----- hpacucli output -----
hpacucli controller slot=0 show config

Smart Array P400 in Slot 0 (Embedded) (sn: PAFGL0T9SXU2RB)

array A (SATA, Unused Space: 0 MB)


logicaldrive 1 (232.9 GB, RAID 1, OK)

physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 250 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 250 GB, OK)

array B (SATA, Unused Space: 0 MB)


logicaldrive 2 (1.8 TB, RAID 1+0, Interim Recovery Mode)

physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 1 TB, OK)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 1 TB, OK)
physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 1 TB, OK)
physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 0 MB, Failed)


------ check_hparray output ------

RAID OK - (Smart Array P400 in Slot 0 (Embedded) array A logicaldrive 1 (232.9 GB, RAID 1, OK) array B logicaldrive 2 (1.8 TB, RAID 1+0, Interim Recovery Mode))

ZsZs
byjdecello, March 20, 2010
1 of 1 people found this review helpful
it works sort of. It worked fine on the command line, even as user nagios (so yes, I did setup /etc/sudoers correctly). However, it didn't work from nagios3 nrpe...

Also, having to hard code slots isn't very convinient...... there is a better check.

I tried another one like this, in perl, but that one was broken too.... didn't support slot=0.

The best one, was this one, check_hpccis written by Simone Rosa. That one gave verbose output -v, scanned all arrays... very similiar to this one, yet that one worked out of the box with nagios3.