Great work on this. I’m having an issue monitoring a Xerox DocuColor 242 though. The reported toner levels fluctuate wildly every few minutes. Here is an example from CONSUM ALL:
Black Toner [K] Cartridge is at 253% – OK! Black Drum Cartridge is at 55% – OK! Black Toner [K1] Cartridge is at 1084% – OK! Black Toner [K2] Cartridge is at 884% – OK! | Black Toner [K] Cartridge=253;20;5; Black Drum Cartridge=55;20;5; Black Toner [K1] Cartridge=1084;20;5; Black Toner [K2] Cartridge=884;20;5;
Black Toner [K] Cartridge is at 15% – WARNING! Black Drum Cartridge is at 17% – WARNING! Black Toner [K1] Cartridge is at 1590% – OK! Black Toner [K2] Cartridge is at 1071% – OK! | Black Toner [K] Cartridge=15;20;5; Black Drum Cartridge=17;20;5; Black Toner [K1] Cartridge=1590;20;5; Black Toner [K2] Cartridge=1071;20;5;
This is for all consumables. Actual levels for K1 and K2 are 20% and 100%.
All other checks work. Tray levels look correct. Tray 5 says to refill it with .5 x .5 paper but it is set to 8.5×11.
Thanks.