Build precise queries to find exactly what you need
Press ESC to close
@suesst
Favorites0
Views
Projects0
Hi, great plugin, the only thing I recognized is, that it detect disk errors(as an experiment, I pulled out a disk out of raid 5), but the status is not set to warning or critical. Here is the verbose output: 20100525 16:49:12 Check classe CIM_ComputerSystem 20100525 16:49:12 Element Name = System Board 7:1 20100525 16:49:12 Element Op Status = 0 20100525 16:49:12 Element Name = System Internal Expansion Board 16:1 20100525 16:49:12 Element Op Status = 0 20100525 16:49:12 Element Name = System Internal Expansion Board 16:2 20100525 16:49:12 Element Op Status = 0 20100525 16:49:12 Element Name = System Internal Expansion Board 16:5 20100525 16:49:12 Element Op Status = 0 20100525 16:49:12 Element Name = esx-test01.roland-domaene.intra 20100525 16:49:12 Element Name = Hardware Management Controller (Node 0) 20100525 16:49:12 Element Op Status = 0 20100525 16:49:12 Element Name = HP Smart Array P400 Controller : HPSA1 20100525 16:49:12 Check classe CIM_NumericSensor 20100525 16:49:12 Element Name = System Board 1 Power Meter 20100525 16:49:12 Element Op Status = 2 20100525 16:49:12 Element Name = Power Domain 1 Temp 5 20100525 16:49:12 Element Op Status = 2 20100525 16:49:12 Element Name = Processor 11 Temp 4 20100525 16:49:12 Element Op Status = 2 20100525 16:49:12 Element Name = Processor 10 Temp 3 20100525 16:49:12 Element Op Status = 2 20100525 16:49:12 Element Name = External Environment 9 Temp 2 20100525 16:49:12 Element Op Status = 2 20100525 16:49:12 Element Name = System Internal Expansion Board 5 Temp 1 20100525 16:49:12 Element Op Status = 2 20100525 16:49:12 Element Name = Processor 4 Fan 6 20100525 16:49:12 Element Op Status = 2 20100525 16:49:12 Element Name = Processor 3 Fan 5 20100525 16:49:12 Element Op Status = 2 20100525 16:49:12 Element Name = Processor 2 Fan 4 20100525 16:49:12 Element Op Status = 2 20100525 16:49:12 Element Name = Processor 1 Fan 3 20100525 16:49:12 Element Op Status = 2 20100525 16:49:12 Element Name = System Internal Expansion Board 2 Fan 2 20100525 16:49:12 Element Op Status = 2 20100525 16:49:12 Element Name = System Internal Expansion Board 1 Fan 1 20100525 16:49:12 Element Op Status = 2 20100525 16:49:12 Check classe CIM_Memory 20100525 16:49:12 Element Name = Proc 1 Level-1 Cache 20100525 16:49:12 Element Op Status = 0 20100525 16:49:12 Element Name = Proc 1 Level-1 Cache 20100525 16:49:12 Element Op Status = 0 20100525 16:49:12 Element Name = Proc 1 Level-1 Cache 20100525 16:49:12 Element Op Status = 0 20100525 16:49:12 Element Name = Proc 1 Level-1 Cache 20100525 16:49:12 Element Op Status = 0 20100525 16:49:12 Element Name = Proc 1 Level-2 Cache 20100525 16:49:12 Element Op Status = 0 20100525 16:49:12 Element Name = Proc 1 Level-2 Cache 20100525 16:49:12 Element Op Status = 0 20100525 16:49:12 Element Name = Proc 1 Level-2 Cache 20100525 16:49:12 Element Op Status = 0 20100525 16:49:12 Element Name = Proc 1 Level-2 Cache 20100525 16:49:12 Element Op Status = 0 20100525 16:49:12 Element Name = Proc 1 Level-3 Cache 20100525 16:49:12 Element Op Status = 0 20100525 16:49:12 Element Name = Memory 20100525 16:49:12 Check classe CIM_Processor 20100525 16:49:13 Element Name = Proc 1 20100525 16:49:13 Element Op Status = 2 20100525 16:49:13 Check classe CIM_RecordLog 20100525 16:49:13 Element Name = IPMI SEL 20100525 16:49:13 Element Op Status = 2 20100525 16:49:13 Check classe OMC_DiscreteSensor 20100525 16:49:13 Element Name = System Board 1 Fans 20100525 16:49:13 Element Op Status = 2 20100525 16:49:13 Element Name = Processor Module 1 VRM 1 20100525 16:49:13 Element Name = Power Supply 3 Power Supplies 20100525 16:49:13 Element Op Status = 2 20100525 16:49:13 Element Name = Power Supply 2 Power Supply 2: Presence detected 20100525 16:49:13 Element Name = Power Supply 2 Power Supply 2: Failure detected 20100525 16:49:13 Element Op Status = 2 20100525 16:49:13 Element Name = Power Supply 1 Power Supply 1: Presence detected 20100525 16:49:13 Element Name = Power Supply 1 Power Supply 1: Failure detected 20100525 16:49:13 Element Op Status = 2 20100525 16:49:13 Element Name = System Chassis 3 Ext. Health LED 20100525 16:49:13 Element Name = System Chassis 2 Int. Health LED 20100525 16:49:13 Element Name = System Chassis 1 UID Light 20100525 16:49:13 Check classe VMware_StorageExtent 20100525 16:49:13 Element Name = Disk 1 on HPSA1 : Port 1I Box 1 Bay 6 : 136GB : Data Disk : Disk Error 20100525 16:49:13 Element Name = Disk 2 on HPSA1 : Port 1I Box 1 Bay 5 : 136GB : Data Disk 20100525 16:49:13 Element Name = Disk 3 on HPSA1 : Port 2I Box 1 Bay 3 : 136GB : Data Disk 20100525 16:49:13 Element Name = Disk 4 on HPSA1 : Port 2I Box 1 Bay 2 : 136GB : Data Disk 20100525 16:49:13 Element Name = Disk 5 on HPSA1 : Port 2I Box 1 Bay 1 : 136GB : Data Disk 20100525 16:49:13 Check classe VMware_Controller 20100525 16:49:13 Element Name = HP Smart Array P400 Controller : HPSA1 20100525 16:49:13 Check classe VMware_StorageVolume 20100525 16:49:13 Element Name = Logical Volume 1 on HPSA1 : RAID 5 : 546GB : Disk 1,2,3,4,5 : Interim Recovery 20100525 16:49:13 Check classe VMware_Battery 20100525 16:49:14 Element Name = Battery on HPSA1 20100525 16:49:14 Check classe VMware_SASSATAPort OK
Reviewed 15 years ago