Hi! I also tested on ix4-200d and the memory error ocurrs. But, I compared and changed the OID from the memory check, so it's working fine now. Here's the new one: * Size: .1.3.6.1.2.1.25.2.3.1.5.1 * Used: .1.3.6.1.2.1.25.2.3.1.6.1 Although, by the MIB file that came with it, your values are supposed to work. Hope it helps you, and thanks for this nice plugin!