Nagios Exchange Nagios Exchange
  • Home
  • Directory
  • Library
  • Support
  • About
  • Submit Feedback

Advanced Search

Build precise queries to find exactly what you need

Search Logic

Select compatible versions

Press ESC to close

Sign In Sign Up

Nagios World Conference 2026: Sept. 14-17 in St. Paul, MN | Learn More

  • Home
  • Directory
  • Library
  • Support
  • About
  • Submit Feedback
Plugins4405Themes and Skins13Add-ons759Graphics and Logos36View All Categories
LinuxSecuritySNMPFile SystemCloud
New Listings Recently Updated Listings Most Favored Listings Most Popular Listings Most Rated Listings Most Reviewed Listings
Random Project
Clustering and High-Availability check_ibm_biginsights_agents.pl (Advanced Nagios Plugins Collection)
0.0 (0)
20.4K
RSS Feed
Newest Listings Updated Listings
Top Contributors
deskwork_itunes142 (4)Chad Columbus (3)Marcin Bednarski (3)Davide Lemma (3)Sam N (2)
See More
Newest Contributors
matthewducey (1)Linuxfabrik (1)signalgrid (1)Sanna Glue (2)fisherrs (1)
See More

Copyright © 2009-2026 Nagios Enterprises, LLC. All rights reserved.

Privacy PolicyTerms of UseTrademarks
Home > Eric Aiken
EA

Eric Aiken

@EricAiken

User Stats

Member Since: July 19, 2013

Favorites0

Views

Projects0

No Projects Found
Powershell NRPE NSClient script for HP SmartArray check

Thought on this

Looking forward to this plugin but getting some errors: Any thoughts? Running on win2k3 x64. I have a few print here statements trying to locate where the errors are coming from. c:Userseric.aikenDownloads>powershell -File check_smartarray.ps1 -t30 -c check_raid here0 Smart Array P410i in Slot 0 (Embedded) (sn: 5001438018A01EB0) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (1.6 TB, RAID 5, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 900.1 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 900.1 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 900.1 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 5001438018A01EBF) here1 Smart Array P410i in Slot 0 (Embedded) (sn: 5001438018A01EB0) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (1.6 TB, RAID 5, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 900.1 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 900.1 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 900.1 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 5001438018A01EBF) here2 Name Value ---- ----- Array 0 - lv System.Collections.DictionaryEntry Array 0 - pd {System.Collections.DictionaryEntry, System.Collections.DictionaryEntry, System.Collections.Dictiona... Cannot index into a null array. At C:Userseric.aikenDownloadscheck_smartarray.ps1:94 char:77 + return ($state | Select-String -Pattern "(?Id : MethodNotFound Method invocation failed because [System.Object[]] doesn't contain a method named 'ContainsKey'. At C:Userseric.aikenDownloadscheck_smartarray.ps1:190 char:25 + if ($errors.ContainsKey tain a method named 'ContainsKey'. At C:Userseric.aikenDownloadscheck_smartarray.ps1:190 char:25 + if ($errors.ContainsKey

Reviewed 13 years ago

No Favorites Found

Copyright © 2009-2026 Nagios Enterprises, LLC. All rights reserved.

Privacy PolicyTerms of UseTrademarks
Home Browse Submit Profile