Nagios Exchange Nagios Exchange
  • Home
  • Directory
  • Library
  • Support
  • About

Advanced Search

Build precise queries to find exactly what you need

Search Logic

Select compatible versions

Press ESC to close

Sign In Sign Up
  • Home
  • Directory
  • Library
  • Support
  • About
Plugins4391Themes and Skins12Add-ons741Documentation283Graphics and Logos36View All Categories
LinuxSecuritySNMPFile SystemCloud
New Listings Recently Updated Listings Most Favored Listings Most Popular Listings Most Rated Listings Most Reviewed Listings
Random Project
Nagios XI Documentation Source Based NRPE Installation and XI
0.0 (0)
40.3K
RSS Feed
Newest Listings Updated Listings
Top Contributors
Julien DESMAREST (6)LAMY (6)Davide Lemma (4)deskwork_itunes142 (4)Claudio Kuenzler (2)
See More
Newest Contributors
Nitatemic (1)cjdepaul (1)ixs (1)messefreeze (2)apham (1)
See More

Copyright © 2009-2025 Nagios Enterprises, LLC. All rights reserved.

Privacy PolicyTerms of UseTrademarks
Home > Eric Aiken
EA

Eric Aiken

@EricAiken

User Stats

Member Since: July 19, 2013

Favorites0

Views

Projects0

No Projects Found
Powershell NRPE NSClient script for HP SmartArray check

Thought on this

Looking forward to this plugin but getting some errors: Any thoughts? Running on win2k3 x64. I have a few print here statements trying to locate where the errors are coming from. c:Userseric.aikenDownloads>powershell -File check_smartarray.ps1 -t30 -c check_raid here0 Smart Array P410i in Slot 0 (Embedded) (sn: 5001438018A01EB0) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (1.6 TB, RAID 5, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 900.1 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 900.1 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 900.1 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 5001438018A01EBF) here1 Smart Array P410i in Slot 0 (Embedded) (sn: 5001438018A01EB0) array A (SAS, Unused Space: 0 MB) logicaldrive 1 (1.6 TB, RAID 5, OK) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 900.1 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 900.1 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 900.1 GB, OK) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 250 (WWID: 5001438018A01EBF) here2 Name Value ---- ----- Array 0 - lv System.Collections.DictionaryEntry Array 0 - pd {System.Collections.DictionaryEntry, System.Collections.DictionaryEntry, System.Collections.Dictiona... Cannot index into a null array. At C:Userseric.aikenDownloadscheck_smartarray.ps1:94 char:77 + return ($state | Select-String -Pattern "(?Id : MethodNotFound Method invocation failed because [System.Object[]] doesn't contain a method named 'ContainsKey'. At C:Userseric.aikenDownloadscheck_smartarray.ps1:190 char:25 + if ($errors.ContainsKey tain a method named 'ContainsKey'. At C:Userseric.aikenDownloadscheck_smartarray.ps1:190 char:25 + if ($errors.ContainsKey

Reviewed 12 years ago

No Favorites Found

Copyright © 2009-2025 Nagios Enterprises, LLC. All rights reserved.

Privacy PolicyTerms of UseTrademarks
Home Browse Submit Profile