The status for cache being temporarily disabled due to the raid battery charging or discharging is being misreported as a critical alert instead of warning level. Here is a patch that fixes it:
@@ -346,6 +346,9 @@ if echo ${check} | egrep Failed >/dev/null; then echo “RAID CRITICAL – HP Smart Array Failed: “${check} | egrep Failed exit $STATE_CRITICAL +elif echo ${check} | egrep “Cache Status: Temporarily Disabled” >/dev/null; then + echo “RAID WARNING – HP Smart Array Cache Disabled: “${check} + exit $STATE_WARNING elif echo ${check} | egrep Disabled >/dev/null; then echo “RAID CRITICAL – HP Smart Array Problem: “${check} | egrep Disabled exit $STATE_CRITICAL @@ -361,9 +364,6 @@ elif echo ${check2} | egrep Recover >/dev/null; then echo “RAID WARNING – HP Smart Array Recovering: “${check2} | egrep Recover exit $STATE_WARNING -elif echo ${check} | egrep “Cache Status: Temporarily Disabled” >/dev/null; then – echo “RAID WARNING – HP Smart Array Cache Disabled: “${check} – exit $STATE_WARNING elif echo ${check} | egrep FIRMWARE >/dev/null; then echo “RAID WARNING – “${check} exit $STATE_WARNING