same error here but i suspect a perl library update to have it broken because it worked before. here the verbose log i get on a cisco server
20110824 09:53:36 Connection to https://10.47.5.251 20110824 09:53:36 Check classe OMC_SMASHFirmwareIdentity 20110824 09:53:36 Element Name = System BIOS 20110824 09:53:36 VersionString = C200.1.3.1c.0.021920110242 20110824 09:53:36 Check classe CIM_Chassis 20110824 09:53:37 Element Name = Chassis 20110824 09:53:37 Manufacturer = Cisco Systems Inc 20110824 09:53:37 SerialNumber = QCI1424A0WS 20110824 09:53:37 Model = R210-2121605W 20110824 09:53:37 Element Op Status = 0 20110824 09:53:37 Check classe CIM_Card 20110824 09:53:37 Element Name = Server Blade 20110824 09:53:37 SerialNumber = QCI1423A2CW 20110824 09:53:37 Element Op Status = 0 20110824 09:53:37 Check classe CIM_ComputerSystem 20110824 09:53:38 Element Name = System Board 7:0 20110824 09:53:38 Element Op Status = 0 20110824 09:53:38 Element Name = System Board 7:24 20110824 09:53:38 Element Op Status = 0 20110824 09:53:38 Element Name = System Board 7:29 20110824 09:53:38 Element Op Status = 0 20110824 09:53:38 Element Name = System Board 7:30 20110824 09:53:38 Element Op Status = 0 20110824 09:53:38 Element Name = System Board 7:31 20110824 09:53:38 Element Op Status = 0 20110824 09:53:38 Element Name = System Board 7:32 20110824 09:53:38 Element Op Status = 0 20110824 09:53:38 Element Name = System Board 7:33 20110824 09:53:38 Element Op Status = 0 20110824 09:53:38 Element Name = Add-in Card 11:0 20110824 09:53:38 Element Op Status = 0 20110824 09:53:38 Element Name = Add-in Card 11:1 20110824 09:53:38 Element Op Status = 0 20110824 09:53:38 Element Name = esx01.sab.be 20110824 09:53:38 Element Name = Hardware Management Controller (Node 0) 20110824 09:53:38 Element Op Status = 0 20110824 09:53:38 Element Name = Controller 0 (LSI MegaRAID SAS 9261-8i) 20110824 09:53:38 Element Op Status = 2 20110824 09:53:38 Check classe CIM_NumericSensor Traceback (most recent call last): File “check_esxi_hardware.py”, line 493, in ? instance_list = wbemclient.EnumerateInstances(classe) File “/usr/lib/python2.4/site-packages/pywbem/cim_operations.py”, line 403, in EnumerateInstances ClassName = CIMClassName(ClassName), File “/usr/lib/python2.4/site-packages/pywbem/cim_operations.py”, line 178, in imethodcall reply_dom = minidom.parseString(resp_xml) File “/usr/lib/python2.4/site-packages/_xmlplus/dom/minidom.py”, line 1925, in parseString return expatbuilder.parseString(string) File “/usr/lib/python2.4/site-packages/_xmlplus/dom/expatbuilder.py”, line 942, in parseString return builder.parseString(string) File “/usr/lib/python2.4/site-packages/_xmlplus/dom/expatbuilder.py”, line 223, in parseString parser.Parse(string, True) xml.parsers.expat.ExpatError: not well-formed (invalid token): line 2759, column 7