Check script for HP LeftHand SAN/iQ devices. Gives status of hardware, drive information and array information.
Current Version
1.3
Last Release Date
2015-11-09
Owner
Tom Paah
License
GPL
Compatible With
Check script
Uses SNMP queries to fetch information.
Built and tested on following SAN/IQ versions 11.5.00.0673.0 12.0.00.0725.0
Will raise WARNING condition on most hardware or array based faults. Drive temperature can generate CRITICAL condition.
Usage: ./check_lefthand.sh [-v] -H host[:port] -C community [-T test type]
Options: -h Print detailed help screen -H HP Lefthand host address and optional port -C HP Lefthand SNMP read community. Default is 'public' -T Test type. Can be one of following info - General information about the unit (default) drives - Detailed information about the units drives arrays - Detailed information about the units RAID arrays
Typical output from test type info: OK System: P4500G2 MYNAS01, SN: CZJ123456A, 12 600GB SAS 3.0Gbps drives, SAN/iQ 11.5.00.0673.0|CPU_1_temp=40C;78;80 MLB_inlet_temp=18C;38;40 Cache 1 Normal Fan1 Normal Fan2 Normal Fan3 Normal Fan4 Normal CPU (1) at 40 deg C MLB inlet at 18 deg C PowerSupply1 Normal PowerSupply2 Normal
Typical output from test type drives: OK 12 drives|Drive_1_temp=29C;55;60 Drive_2_temp=28C;55;60 Drive_3_temp=29C;55;60 Drive_4_temp=29C;55;60 Drive_5_temp=29C;55;60 Drive_6_temp=29C;55;60 Drive_7_temp=30C;55;60 Drive_8_temp=30C;55;60 Drive_9_temp=31C;55;60 Drive_10_temp=31C;55;60 Drive_11_temp=32C;55;60 Drive_12_temp=33C;55;60 Drive 1 Active (SN: JZW1ABCD, Temp: 29C, SMART health: Normal) Drive 2 Active (SN: JZW1ABCD, Temp: 28C, SMART health: Normal) Drive 3 Active (SN: JZW1ABCD, Temp: 29C, SMART health: Normal) Drive 4 Active (SN: JZW1ABCD, Temp: 29C, SMART health: Normal) Drive 5 Active (SN: JZW1ABCD, Temp: 29C, SMART health: Normal) Drive 6 Active (SN: JZW1ABCD, Temp: 29C, SMART health: Normal) Drive 7 Active (SN: JZW1ABCD, Temp: 30C, SMART health: Normal) Drive 8 Active (SN: JZW1ABCD, Temp: 30C, SMART health: Normal) Drive 9 Active (SN: JZW1ABCD, Temp: 31C, SMART health: Normal) Drive 10 Active (SN: JZW1ABCD, Temp: 31C, SMART health: Normal) Drive 11 Active (SN: JZW1ABCD, Temp: 32C, SMART health: Normal) Drive 12 Active (SN: JZW1ABCD, Temp: 33C, SMART health: Normal)
Typical output from test type arrays: OK 2 arrays| Data Array 1 (RAID5, 6 disks, State Normal, Size 2712 GB) Data Array 2 (RAID5, 6 disks, State Normal, Size 2724 GB)
Update history: 1.0 First release 1.2 Bug fix with return data when array was faulty 1.3 Improved error handling (if hosts are down)
Hi, Thanks for your great plugin! I made some changes, including exiting CRITICAL state when was WARNING and sending the perfdata to the end of the output string.
You must be logged in to submit a review.
To:
From:
We’ve completely redesigned the world’s largest repository of Nagios plugins and monitoring tools. Join thousands of users sharing monitoring solutions for servers, applications, and everything in between.
Due to our redesign, all existing accounts require a password reset to access your account again.
Ready to explore 6,100+ projects and contribute to the community?
Reset Password Create Account
Happy Monitoring!