############################ # Dell OpenManage SNMP Traps ############################ # Thermal shutdown protection has been initiated traphandle MIB-Dell-10892::alertThermalShutdown /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1004 # Temperature sensor returned to a normal value traphandle MIB-Dell-10892::alertTemperatureProbeNormal /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1052 # Temperature sensor detected a warning value traphandle MIB-Dell-10892::alertTemperatureProbeWarning /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1053 # Temperature sensor detected a failure value traphandle MIB-Dell-10892::alertTemperatureProbeFailure /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1054 # Temperature sensor detected a non-recoverable value traphandle MIB-Dell-10892::alertTemperatureProbeNonRecoverable /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1055 # Fan sensor returned to a normal value traphandle MIB-Dell-10892::alertCoolingDeviceNormal /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1102 # Fan sensor detected a warning value traphandle MIB-Dell-10892::alertCoolingDeviceWarning /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1103 # Fan sensor detected a failure value traphandle MIB-Dell-10892::alertCoolingDeviceFailure /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1104 # Fan sensor detected a non-recoverable value traphandle MIB-Dell-10892::alertCoolingDeviceNonRecoverable /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1105 # Voltage sensor returned to a normal value traphandle MIB-Dell-10892::alertVoltageProbeNormal /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1152 # Voltage sensor detected a warning value traphandle MIB-Dell-10892::alertVoltageProbeWarning /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1153 # Voltage sensor detected a failure value traphandle MIB-Dell-10892::alertVoltageProbeFailure /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1154 # Voltage sensor detected a non-recoverable value traphandle MIB-Dell-10892::alertVoltageProbeNonRecoverable /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1155 # Current sensor returned to a normal value traphandle MIB-Dell-10892::alertAmperageProbeNormal /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1202 # Current sensor detected a warning value traphandle MIB-Dell-10892::alertAmperageProbeWarning /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1203 # Current sensor detected a failure value traphandle MIB-Dell-10892::alertAmperageProbeFailure /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1204 # Current sensor detected a non-recoverable value traphandle MIB-Dell-10892::alertAmperageProbeNonRecoverable /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1205 # Chassis intrusion returned to a normal value traphandle MIB-Dell-10892::alertChassisIntrusionNormal /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1252 # Chassis intrusion detected traphandle MIB-Dell-10892::alertChassisIntrusionDetected /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1254 # Redundancy regained traphandle MIB-Dell-10892::alertRedundancyNormal /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1304 # Redundancy degraded traphandle MIB-Dell-10892::alertRedundancyDegraded /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1305 # Redundancy lost traphandle MIB-Dell-10892::alertRedundancyLost /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1306 # Power supply returned to a normal value traphandle MIB-Dell-10892::alertPowerSupplyNormal /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1352 # Power supply detected a failure traphandle MIB-Dell-10892::alertPowerSupplyFailure /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1354 # Memory device ECC Correctable error count crossed a warning threshold traphandle MIB-Dell-10892::alertMemoryDeviceWarning /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1403 # Memory device ECC Correctable error count crossed a failure threshold traphandle MIB-Dell-10892::alertMemoryDeviceFailure /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1404 # Memory device ECC Correctable error count crossed a non-recoverablethreshold traphandle MIB-Dell-10892::alertMemoryDeviceNonRecoverable /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1405 # Fan enclosure inserted into system traphandle MIB-Dell-10892::alertFanEnclosureInsertion /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1452 # Fan enclosure removed from system traphandle MIB-Dell-10892::alertFanEnclosureRemoval /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1453 # Fan enclosure removed from system for an extended amount of time traphandle MIB-Dell-10892::alertFanEnclosureExtendedRemoval /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1454 # Power cord is not being monitored traphandle MIB-Dell-10892::alertACPowerCordNoPowerNonRedundant /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1501 # AC power has been restored traphandle MIB-Dell-10892::alertACPowerCordNormal /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1502 # AC power has been lost traphandle MIB-Dell-10892::alertACPowerCordFailure /usr/lib/nagios/plugins/handle-dell-openmanage-trap 1504